The modalias string of devices that represent units on a FireWire node
did not show Module_ID entries within unit directories. This was
because firewire-core searched only the root directory of the
configuration ROM for a Model_ID entry.
We now search first the root directory, then the unit directory. IOW
honor a unit directory's Model_ID if present, otherwise fall back to the
root directory's model ID (if present).
Furthermore, apply the same change to Vendor_ID. This had the same
issue but it was less apparent because most devices provide Vendor_ID
only in the root directory.
And finally, also use this strategy for the remaining two IDs in the
modalias, Specifier_ID and Version. It does not actually make sense to
look for them elsewhere than in the unit directory because they are
mandatory there. However, a uniform search order simplifies the
implementation and has no adverse affect in practice.
Side notes:
- The older counterpart of this, nodemgr.c of ieee1394, looked for
Vendor_ID first in the root directory, then in the unit directory,
and for Model_ID only in the unit directory.
- There is a single mainline driver which requires Vendor_ID and
Model_ID --- the firedtv driver. This one worked because FireDTVs
provide Vendor_ID in the root directory and Model_ID identically in
root directory and unit directory.
- Apart from firedtv, there are currently no drivers known to me
(including userspace drivers) that look at the Vendor_ID or Model_ID
of the modalias.
Reported-by:
Maciej Żenczykowski <zenczykowski@gmail.com>
Signed-off-by:
Stefan Richter <stefanr@s5r6.in-berlin.de>