drivers: can: mcan: switch from tx fifo to tx queue
Switch the Bosch M_CAN driver from TX FIFO mode to TX Queue mode in
order to avoid priority inversion of CAN frames.
Fixes: #26541
Signed-off-by:
Henrik Brix Andersen <hebad@vestas.com>
Loading