Commit fd96a316 authored by Yuantian Tang's avatar Yuantian Tang Committed by Daniel Lezcano
Browse files

dt-bindings: thermal: make cooling-maps property optional



Cooling-maps doesn't have to be a required property because there may
be no cooling device on system, or there are no enough cooling devices for
each thermal zone in multiple thermal zone cases since cooling devices
can't be shared.
So make this property optional to remove such limitations.

For thermal zones with no cooling-maps, there could be critic trips
that can trigger CPU reset or shutdown. So they still can take actions.

Signed-off-by: default avatarYuantian Tang <andy.tang@nxp.com>
Reviewed-by: default avatarAmit Kucheria <amit.kucheria@linaro.org>
Signed-off-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200309045411.21859-1-andy.tang@nxp.com
parent 01c354e2
Loading
Loading
Loading
Loading
+1 −1
Original line number Diff line number Diff line
@@ -142,11 +142,11 @@ Required properties:
- trips:		A sub-node which is a container of only trip point nodes
  Type: sub-node	required to describe the thermal zone.

Optional property:
- cooling-maps:		A sub-node which is a container of only cooling device
  Type: sub-node	map nodes, used to describe the relation between trips
			and cooling devices.

Optional property:
- coefficients:		An array of integers (one signed cell) containing
  Type: array		coefficients to compose a linear relation between
  Elem size: one cell	the sensors listed in the thermal-sensors property.