MVEBU thermal IP supports multiple channels. Each channel may have several sensors but for now each channel is wired to only one thermal sensor. The first channel always points to the so called internal sensor, within the thermal IP. There is usually one more channel (with one sensor each time) per CPU. The code has been written to support possible evolutions of the ap806 IP that would embed more CPUs and thus more channels to select. Each channel should be referenced in the device tree as an independent thermal zone. Add the possibility to read each of these sensors through sysfs by registering all the sensors (translated in "thermal_zone"). Also add a mutex on these accesses to avoid read conflicts (only one channel/sensor may be selected and read at a time). Signed-off-by:Miquel Raynal <miquel.raynal@bootlin.com> Signed-off-by:
Eduardo Valentin <edubezval@gmail.com>