Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
This commit enables the active pullup (APU bit) by default for
the DS2482 1-Wire master.
>From the DS2482 datasheet:
"The APU bit controls whether an active pullup (controlled slew-rate
transistor) or a passive pullup (Rwpu resistor) will be used to drive
a 1-Wire line from low to high. When APU = 0, active pullup is disabled
(resistor mode). Active Pullup should always be selected unless there is
only a single slave on the 1-Wire line."
According to the module author, Ben Gardner:
"It doesn't look like active pullup would cause any hurt if there
is only a single slave."
And my tests with multiple and single slaves on 1-Wire bus
confirms that.
This active pullup can be manually disabled using the introduced
module parameter:
active_pullup = 0