+39
−0
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
In SGMII mode, we observed an autonegotiation issue after power-down-up cycles where the copper side reports successful link establishment but the SGMII side's link is down. This happened in a setup where the at8031 is connected over SGMII to a eTSEC (fsl gianfar), but so far could not be reproduced with other Ethernet device / driver combinations. This commit adds a wrapper function for at8031 that in case of operating in SGMII mode double checks SGMII link state when generic aneg_done() succeeds. It prints a warning on failure but intentionally does not try to recover from this state. As a result, if you ever see a warning '803x_aneg_done: SGMII link is not ok' you will end up having an Ethernet link up but won't get any data through. This should not happen, if it does, please contact the module maintainer. Signed-off-by:Zefir Kurtisi <zefir.kurtisi@neratec.com> Signed-off-by:
David S. Miller <davem@davemloft.net>