+2
−2
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Some regulator drivers may be defining very long names: this is the
case with the qcom_smd and qcom_spmi regulators, where we need to
parse the regulator parents from DT.
For clarity, this is an example:
{ "l13a", QCOM_SMD_RPM_LDOA, 13, &pm660_ht_lvpldo,
"vdd_l8_l9_l10_l11_l12_l13_l14" },
pm660-regulators {
...
vdd_l8_l9_l10_l11_l12_l13_l14-supply = <&vreg_s4a_2p04>
...
};
Now, with a 32 characters limit, the function is trying to parse,
exactly, "vdd_l8_l9_l10_l11_l12_l13_l14-s" (32 chars) instead of
the right one, which is 37 chars long in this specific case.
... And this is not only the case with PM660/PM660L, but also with
PMA8084, PM8916, PM8950 and others that are not implemented yet.
The length of 64 chars was chosen based on the longest parsed property
name that I could find, which is in PM8916, and would be 53 characters
long.
At that point, rounding that to 64 looked like being the best idea.
Signed-off-by:
AngeloGioacchino Del Regno <kholk11@gmail.com>
Link: https://lore.kernel.org/r/20200926125549.13191-2-kholk11@gmail.com
Signed-off-by:
Mark Brown <broonie@kernel.org>