+45
−9
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
QCA6390 memdump VSE sometimes come to bluetooth driver with wrong sequence number as illustrated as follows: frame # in dec: frame data in hex 1396: ff fd 01 08 74 05 00 37 8f 14 1397: ff fd 01 08 75 05 00 ff bf 38 1414: ff fd 01 08 86 05 00 fb 5e 4b 1399: ff fd 01 08 77 05 00 f3 44 0a 1400: ff fd 01 08 78 05 00 ca f7 41 it is mistook for controller missing packets, so results in page fault after overwriting memdump buffer allocated. Fixed by ignoring QCA6390 sequence number check and checking buffer space before writing. Signed-off-by:Zijun Hu <zijuhu@codeaurora.org> Tested-by:
Zijun Hu <zijuhu@codeaurora.org> Signed-off-by:
Marcel Holtmann <marcel@holtmann.org>
CRA Git | Maintained and supported by SUSTech CRA and CCSE