No alarm is reported by /sys/.../inX_alarm In detail: The SMI Voltage status register is the only register giving a status for voltages, but it does not work like the non-SMI status registers used for temperatures and fans. A bit is set for each input crossing a threshold, in both direction, but the "inside" or "outside" limits info is not available. Also this register is cleared on read. Note : this is not explicitly spelled out in the datasheet, but from experiment. As a result if an input is crossing a threshold (min or max in any direction), the alarm is reported only once even if the input is still outside limits. Also if the alarm for another input is read before the one of this input, no alarm is reported at all. Signed-off-by:Gilles Buloz <gilles.buloz@kontron.com> Link: https://lore.kernel.org/r/5de0f566.tBga5POKAgHlmd0p%gilles.buloz@kontron.com Fixes: 3434f378 ("hwmon: Driver for Nuvoton NCT7802Y") Signed-off-by:
Guenter Roeck <linux@roeck-us.net>