+1
−1
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
I've noticed that my CSR usb dongle was not working if it was plugged in when
PC was booting. It looks like I get two HCI reset command complete events (see
hcidump logs below).
The root cause is reset called from off_timer. Timeout for this reset to
complete is set to 250ms and my bt dongle requires more time for replying with
command complete event. After that, chip seems to reply with reset command
complete event for next non-reset command.
Attached patch increase mentioned timeout to HCI_INIT_TIMEOUT, this value is
already used for timeouting hci_reset_req in hci_dev_reset().
This might also be related to BT not working after suspend that was reported
here some time ago.
Hcidump log:
2011-09-12 23:13:27.379465 < HCI Command: Reset (0x03|0x0003) plen 0
2011-09-12 23:13:27.380797 > HCI Event: Command Complete (0x0e) plen 4
Reset (0x03|0x0003) ncmd 1
status 0x00
2011-09-12 23:13:27.380859 < HCI Command: Read Local Supported Features (0x04|0x000
3) plen 0
2011-09-12 23:13:27.760789 > HCI Event: Command Complete (0x0e) plen 4
Reset (0x03|0x0003) ncmd 1
status 0x00
2011-09-12 23:13:27.760831 < HCI Command: Read Local Version Information (0x04|0x00
01) plen 0
2011-09-12 23:13:27.764780 > HCI Event: Command Complete (0x0e) plen 12
Read Local Version Information (0x04|0x0001) ncmd 1
status 0x00
HCI Version: 1.1 (0x1) HCI Revision: 0x36f
LMP Version: 1.1 (0x1) LMP Subversion: 0x36f
Manufacturer: Cambridge Silicon Radio (10)
Signed-off-by:
Szymon Janc <szymon@janc.net.pl>
Signed-off-by:
Gustavo F. Padovan <padovan@profusion.mobi>
CRA Git | Maintained and supported by SUSTech CRA and CCSE