im6sl reference manual 47.7.4:
"
Bit clock - Used to serially clock the data bits in and out of the SSI port.
This clock is either generated internally (from SSI's sys clock) or taken
from external clock source (through the Tx/Rx clock ports).
[...]
Care should be taken to ensure that the bit clock frequency (either
internally generated by dividing the SSI's sys clock or sourced from
external device through Tx/Rx clock ports) is never greater than 1/5
of the ipg_clk (from CCM) frequency.
"
Since, in master mode, the sysclk is a multiple of bitclk, we can
easily reach a high sysclk value, whereas keeping a reasonable bitclk.
ex: 8ch x 16bit x 48kHz = 6144000, requires a 24576000 sysclk (PM=1)
yet ipg_clk/5 = 66Mhz/5 = 13.2
Signed-off-by:
Arnaud Mouiche <arnaud.mouiche@invoxia.com>
Reviewed-by:
Fabio Estevam <fabio.estevam@nxp.com>
Tested-by:
Caleb Crome <caleb@crome.org>
Signed-off-by:
Mark Brown <broonie@kernel.org>