Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
The fnic driver with FIP is reporting link up, even though it's down. When the interface is shut down by the switch, we receive a clear virtual link, and set the state reported to libfc as down, although we still report it up. Clearly wrong. That causes the subsequent link down event not to be reported, and /sys shows the host "Online". Currently, in FIP mode, if an FCF times out, then link to libfc is reported as down, to stop FLOGIs. That interferes with the LLD link down being reported. Users really need to know the physical link information, to diagnose cabling issues, so physical link status should be reported to libfc. If the selected FCF needs to be reported, that should be done separately, in a later patch. Signed-off-by:Joe Eykholt <jeykholt@cisco.com> Signed-off-by:
Robert Love <robert.w.love@intel.com> Signed-off-by:
James Bottomley <James.Bottomley@suse.de>