Commit da6e0f70 authored by Chaotian Jing's avatar Chaotian Jing Committed by Ulf Hansson
Browse files

mmc: mediatek: fix controller busy when plug out SD



when plug out SD card, may get data CRC error, the MMC core will issue
CMD13 to get card status, then CMD13 timeout(due to card plug out) will
trigger CMD19 tuning, first CMD19 timeout has not call msdc_reset_hw()
and cause the next CMD19 gets controller busy.

Signed-off-by: default avatarChaotian Jing <chaotian.jing@mediatek.com>
Signed-off-by: default avatarUlf Hansson <ulf.hansson@linaro.org>
parent bb716606
Loading
Loading
Loading
Loading
+5 −3
Original line number Diff line number Diff line
@@ -1071,11 +1071,13 @@ static bool msdc_cmd_done(struct msdc_host *host, int events,
	}

	if (!sbc_error && !(events & MSDC_INT_CMDRDY)) {
		if (cmd->opcode != MMC_SEND_TUNING_BLOCK &&
		    cmd->opcode != MMC_SEND_TUNING_BLOCK_HS200)
		if (events & MSDC_INT_CMDTMO ||
		    (cmd->opcode != MMC_SEND_TUNING_BLOCK &&
		     cmd->opcode != MMC_SEND_TUNING_BLOCK_HS200))
			/*
			 * should not clear fifo/interrupt as the tune data
			 * may have alreay come.
			 * may have alreay come when cmd19/cmd21 gets response
			 * CRC error.
			 */
			msdc_reset_hw(host);
		if (events & MSDC_INT_RSPCRCERR) {