Commit cec8abba authored by Yonglong Liu's avatar Yonglong Liu Committed by David S. Miller
Browse files

net: hns: Fix wrong read accesses via Clause 45 MDIO protocol



When reading phy registers via Clause 45 MDIO protocol, after write
address operation, the driver use another write address operation, so
can not read the right value of any phy registers. This patch fixes it.

Signed-off-by: default avatarYonglong Liu <liuyonglong@huawei.com>
Signed-off-by: default avatarPeng Li <lipeng321@huawei.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent ed29ca8b
Loading
Loading
Loading
Loading
+1 −1
Original line number Diff line number Diff line
@@ -321,7 +321,7 @@ static int hns_mdio_read(struct mii_bus *bus, int phy_id, int regnum)
		}

		hns_mdio_cmd_write(mdio_dev, is_c45,
				   MDIO_C45_WRITE_ADDR, phy_id, devad);
				   MDIO_C45_READ, phy_id, devad);
	}

	/* Step 5: waitting for MDIO_COMMAND_REG 's mdio_start==0,*/