Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
The GMA500 driver is using the legacy GPIO API to fetch three optional display control GPIO lines from the SFI description used by the Medfield platform. Switch this over to use GPIO descriptors and delete the custom platform data. We create three new static locals in the tc35876x bridge code but it is hardly any worse than the I2C client static local already there: I tried first to move it to the DRM driver state container but there are workarounds for probe order in the code so I just stayed off it, as the result is unpredictable. People wanting to do a more throrugh and proper cleanup of the GMA500 driver can work on top of this, I can't solve much more since I don't have access to the hardware, I can only attempt to tidy up my GPIO corner. Cc: Daniel Stone <daniels@collabora.com> Cc: Daniel Vetter <daniel.vetter@ffwll.ch> Reviewed-by:Andy Shevchenko <andriy.shevchenko@linux.intel.com> Acked-by:
Patrik Jakobsson <patrik.r.jakobsson@gmail.com> Link: https://patchwork.freedesktop.org/patch/msgid/20191206094301.76368-1-linus.walleij@linaro.org Signed-off-by:
Linus Walleij <linus.walleij@linaro.org>