The implementation details for SCPI seems to suggest that the sensor readings must be reported by SCP using a well defined scale (millidegree Celsius for temperature, millivolts for voltage, milliamperes for current, microwatts for power and microjoules for energy). This is also important for the interaction with other subsystems: for example both the thermal sub-system and the hwmon sysfs interface expect the temperature expressed in millidegree Celsius. Unfortunately since this behaviour is dependent on the firmware implementation there are cases where the sensor readings are reported using a different scale. For example in the Amlogic SoCs the temperature is reported in degree and not millidegree Celsius. To take into account this discrepancy and fixup the values reported by SCP a new compatible 'amlogic,meson-gxbb-scpi-sensors' is introduced and used in this patch by the scpi-hwmon driver to convert the sensor readings to the expected scale. Signed-off-by:Carlo Caione <carlo@endlessm.com> Acked-by:
Sudeep Holla <sudeep.holla@arm.com> Signed-off-by:
Guenter Roeck <linux@roeck-us.net>