+65
−49
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
The io_ti driver fails to download firmware to Edgeport devices such as the EP/416, even when the on-disk firmware image (/lib/firmware/edgeport/down3.bin) is more current than the version on the EP/416. The current download code is broken in a few ways. Notably it mis-uses global variables OperationalMajorVersion and OperationalMinorVersion (reading their values before they've been properly initialized and subsequently initializing them multiple times without synchronization). This patch drops the global variables and replaces the redundant calls to request_firmware()/release_firmware() in download_fw() with a single call pair in edge_startup(); the firmware image pointer is then passed to download_fw() and build_i2c_fw_hdr(). Signed-off-by:Peter E. Berger <pberger@brimson.com> Signed-off-by:
Johan Hovold <johan@kernel.org>