Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Some systems, particularly physically large systems used for early prototyping, may experience substantial voltage drops between the regulator and the consumers as a result of long traces in the system. With these systems voltages may need to be set higher than requested in order to ensure reliable system operation. Allow systems to work around such hardware issues by allowing constraints to supply an offset to be applied to any requested and reported voltages. This is not ideal, especially since the voltage drop may be load dependant, but is sufficient for most affected systems, it is not expected to be used in production hardware. The offset is applied after all constraint processing so constraints should be specified in terms of consumer values not physically configured values. Signed-off-by:Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by:
Liam Girdwood <lrg@slimlogic.co.uk>