Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Current code does integer division (min_vol = min_uV / 1000) before pass min_vol to max8997_get_voltage_proper_val(). So it is possible min_vol is truncated to a smaller value. For example, if the request min_uV is 800900 for ldo. min_vol = 800900 / 1000 = 800 (mV) Then max8997_get_voltage_proper_val returns 800 mV for this case which is lower than the requested voltage. Use uV rather than mV in voltage_map_desc to prevent truncation by integer division. Signed-off-by:Axel Lin <axel.lin@ingics.com> Signed-off-by:
Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: stable@vger.kernel.org