+50
−15
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Commit 98d9986c (ARM: Kirkwood: Replace clock gating) and the fix 5fb2ce (ARM: Kirkwood: clk_register_gate_fn: add fn assignment) introduced a custom variant of clock gating which allows to define a function to be called before gating the clock off. This is used to disable the SATA and PCIe PHYs if the respective clocks are unused after initialization. However, of these two drivers, the SATA driver may be compiled as a module. The driver re-enables the clocks at module init but the PHYs stay disabled. Since the custom clock gating disabled the PHYs when gating the clock off, it should also re-enable them when enabling the clock gate. This is done by adding a second function that may be used to enable the PHYs. Signed-off-by:Simon Baatz <gmbnomis@gmail.com> Signed-off-by:
Andrew Lunn <andrew@lunn.ch>