The current versions of the trf7970a has an erratum where it returns an extra byte in the response to 'Read Multiple Block' (RMB) commands. This command is issued to Type 5 tags (i.e., ISO/IEC 15693 tags) by the neard daemon. To handle this, define a new Device Tree property, 't5t-rmb-extra-byte-quirk', which indicates that the associated trf7970a device has this erratum. The trf7970a device driver will then ensure that the response length to RMB commands is reduced by one byte (for devices with the erratum). Signed-off-by:Mark A. Greer <mgreer@animalcreek.com> Signed-off-by:
Samuel Ortiz <sameo@linux.intel.com>