With a degraded battery, full_charge_capacity can be less than design_capacity, however it's not sure that capacity_now's max will follow. Example from an affected machine: /sys/class/power_supply/BAT0/charge_full -> 4290000 /sys/class/power_supply/BAT0/charge_full_design -> 5900000 /sys/class/power_supply/BAT0/charge_now -> 5900000 /sys/class/power_supply/BAT0/capacity -> 137 The battery is a degraded one with a full charge, and charge_now is the value of charge_full_design instead of charge_full. Added a new quirk to test and correct this, and a new function to check if the battery is a degraded one or not. This keeps the possibility to be over 100 if it's really the case. Signed-off-by:Laszlo Toth <laszlth@gmail.com> Signed-off-by:
Rafael J. Wysocki <rafael.j.wysocki@intel.com>