The PWM in Ingenic SoCs starts in inactive state until the internal timer reaches the duty value, then becomes active until the timer reaches the period value. In theory, we should then use (period - duty) as the real duty value, as a high duty value would otherwise result in the PWM pin being inactive most of the time. This is the reason why the duty value was inverted in the driver until now, but it still had the problem that it would not start with the active part. To address this remaining issue, the common trick is to invert the duty, and invert the polarity when the PWM is enabled. Since the duty was already inverted, and we invert it again, we now program the hardware for the requested duty, and simply invert the polarity when the PWM is enabled. Signed-off-by:Paul Cercueil <paul@crapouillou.net> Signed-off-by:
Thierry Reding <thierry.reding@gmail.com>