The PTM Control register (PCIe r3.1, sec 7.32.3) contains an Effective
Granularity field:
This provides information relating to the expected accuracy of the PTM
clock, but does not otherwise affect the PTM mechanism.
Set the Effective Granularity based on the PTM Root and any intervening PTM
Time Sources.
This does not set Effective Granularity for Root Complex Integrated
Endpoints because I don't know how to figure out clock granularity for
them. The spec says:
... system software must set [Effective Granularity] to the value
reported in the Local Clock Granularity field by the associated PTM
Time Source.
but I don't know how to identify the associated PTM Time Source. Normally
it's the upstream bridge, but an integrated endpoint has no upstream
bridge.
Signed-off-by:
Bjorn Helgaas <bhelgaas@google.com>