Commit 840e1a73 authored by Jerome Brunet's avatar Jerome Brunet
Browse files

clk: meson: check pll rate param table before using it



Make sure the rate param table is available before using it.
Some read-only plls don't provide it, which is ok since the
table is not used by read-only clocks. R/W clocks are supposed
to provide it, but it does not hurt check it.

Signed-off-by: default avatarJerome Brunet <jbrunet@baylibre.com>
parent 7928b2cb
Loading
Loading
Loading
Loading
+10 −0
Original line number Diff line number Diff line
@@ -94,6 +94,13 @@ static long meson_clk_pll_round_rate(struct clk_hw *hw, unsigned long rate,
	const struct pll_rate_table *rate_table = pll->rate_table;
	int i;

	/*
	 * if the table is missing, just return the current rate
	 * since we don't have the other available frequencies
	 */
	if (!rate_table)
		return meson_clk_pll_recalc_rate(hw, *parent_rate);

	for (i = 0; i < pll->rate_count; i++) {
		if (rate <= rate_table[i].rate)
			return rate_table[i].rate;
@@ -109,6 +116,9 @@ static const struct pll_rate_table *meson_clk_get_pll_settings(struct meson_clk_
	const struct pll_rate_table *rate_table = pll->rate_table;
	int i;

	if (!rate_table)
		return NULL;

	for (i = 0; i < pll->rate_count; i++) {
		if (rate == rate_table[i].rate)
			return &rate_table[i];