Commit 83c132ed authored by Guenter Roeck's avatar Guenter Roeck Committed by Mark Yao
Browse files

drm/rockchip: cdn-dp: Load firmware if no monitor connected



If no monitor is connected, suspend/resume cycles result in firmware
load errors because the driver attempts to load the firmware while
the system is in suspend state. This results in a kernel warning and
traceback.

Loading the firmware during boot fixes the problem. Note that we can not
just call schedule_work conditionally in cdn_dp_pd_event() if the insertion
status changed. The problem would still be seen if a monitor is connected
for the first time during suspend.

Signed-off-by: default avatarGuenter Roeck <groeck@chromium.org>
Signed-off-by: default avatarSean Paul <seanpaul@chromium.org>
Signed-off-by: default avatarChris Zhong <zyw@rock-chips.com>
parent 1a0f7ed3
Loading
Loading
Loading
Loading
+1 −6
Original line number Diff line number Diff line
@@ -1021,7 +1021,6 @@ static int cdn_dp_bind(struct device *dev, struct device *master, void *data)
	struct cdn_dp_port *port;
	struct drm_device *drm_dev = data;
	int ret, i;
	bool schedule_event = false;

	ret = cdn_dp_parse_dt(dp);
	if (ret < 0)
@@ -1083,14 +1082,10 @@ static int cdn_dp_bind(struct device *dev, struct device *master, void *data)
				      "register EXTCON_DISP_DP notifier err\n");
			goto err_free_connector;
		}

		if (extcon_get_state(port->extcon, EXTCON_DISP_DP))
			schedule_event = true;
	}

	pm_runtime_enable(dev);

	if (schedule_event)
	schedule_work(&dp->event_work);

	return 0;