+47
−52
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
The Bluetooth subsystem was not using the HCI Reset command when doing
device initialization. The Bluetooth 1.0b specification was ambiguous
on how the device firmware was suppose to handle it. Almost every device
was triggering a transport reset at the same time. In case of USB this
ended up in disconnects from the bus.
All modern Bluetooth dongles handle this perfectly fine and a lot of
them actually require that HCI Reset is sent. If not then they are
either stuck in their HID Proxy mode or their internal structures for
inquiry and paging are not correctly setup.
To handle old and new devices smoothly the Bluetooth subsystem contains
a quirk to force the HCI Reset on initialization. However maintaining
such a quirk becomes more and more complicated. This patch turns the
logic around and lets the old devices disable the HCI Reset command.
The only device where the HCI_QUIRK_NO_RESET is still needed are the
original Digianswer devices and dongles with an early CSR firmware.
CSR reported that they fixed this for version 12 firmware. The last
official release of version 11 firmware is build ID 115. The first
version 12 candidate was build ID 117.
Signed-off-by:
Marcel Holtmann <marcel@holtmann.org>
CRA Git | Maintained and supported by SUSTech CRA and CCSE