Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
On ads7828 the internal reference defaults to off upon power up. When using internal reference, it needs to be turned on and the voltage needs to settle before normal conversion cycle can be started. Hence perform a dummy read in the probe to enable the internal reference allowing the voltage to settle before performing a normal read. Without this fix, the first read from the ADC when using internal reference always returns incorrect data. Signed-off-by:Akshay Bhat <akshay.bhat@timesys.com> Cc: stable@vger.kernel.org # v4.1+ Signed-off-by:
Guenter Roeck <linux@roeck-us.net>