I'm using a Marvell 88E8062 on a custom PPC64 blade and ran into RX lockups while validating the sky2 driver. The receive MAC FIFO would become stuck during testing with high traffic. One port of the 88E8062 would lockup, while the other port remained functional. Re-inserting the sky2 module would not fix the problem - only a power cycle would. I looked over Marvell's most recent sk98lin driver and it looks like they had a "workaround" for the Yukon XL that the sky2 doesn't have yet. The sk98lin driver disables the RX MAC FIFO flush feature for all revisions of the Yukon XL. According to skgeinit.c of the sk98lin driver, "Flushing must be enabled (needed for ASF see dev. #4.29), but the flushing mask should be disabled (see dev. #4.115)". Nice. I implemented this same change in the sky2 driver and verified that the RX lockup I was seeing was resolved. Signed-off-by:Peter Tyser <ptyser@xes-inc.com> Signed-off-by:
Stephen Hemminger <shemminger@linux-foundation.org> Signed-off-by:
Jeff Garzik <jeff@garzik.org>