Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
We've recently switched from extracting the value of HID_DG_CONTACTMAX at a fixed offset (which may not be correct for all tablets) to injecting the report into the driver for the generic codepath to handle. Unfortunately, this change was made for *all* tablets, even those which aren't generic. Because `wacom_wac_report` ignores reports from non- generic devices, the contact count never gets initialized. Ultimately this results in the touch device itself failing to probe, and thus the loss of touch input. This commit adds back the fixed-offset extraction for non-generic devices. Link: https://github.com/linuxwacom/input-wacom/issues/155 Fixes: 184eccd4 ("HID: wacom: generic: read HID_DG_CONTACTMAX from any feature report") Signed-off-by:Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by:
Aaron Armstrong Skomra <aaron.skomra@wacom.com> CC: stable@vger.kernel.org # 5.3+ Signed-off-by:
Benjamin Tissoires <benjamin.tissoires@redhat.com>