Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Implemented Low pass 3db frequency filter which configures FIR and IIR values within the configuration register of EEPROM. For more standardized interface we have fixed the FIR value to 1024, while changes in IIR value are directly connected to filter responses. The new datasheet version will provide a simplified table (also in reStructured text format below) with this change, to provide quick overview of possible settings. Below sensor timings (bandwidth) are calculated for 3db frequency low pass filter. +--------------------+-----------------+ | Filter setting (%) | Band width (Hz) | | (rounded to 1.0) | | +====================+=================+ | 13 | 0.15 | +--------------------+-----------------+ | 17 | 0.20 | +--------------------+-----------------+ | 25 | 0.31 | +--------------------+-----------------+ | 50 | 0.77 | +--------------------+-----------------+ | 57 | 0.86 | +--------------------+-----------------+ | 67 | 1.10 | +--------------------+-----------------+ | 80 | 1.53 | +--------------------+-----------------+ | 100 | 7.23 | +--------------------+-----------------+ The diff is made towards togreg branch. Added myself to MAINTAINERS and authors as per discussion with Jonathan. Signed-off-by:Crt Mori <cmo@melexis.com> Signed-off-by:
Jonathan Cameron <jic23@kernel.org>