Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
As part of moving the thermal bindings to YAML, split it up into 3 bindings: thermal sensors, cooling devices and thermal zones. The property #cooling-cells is required in each device that acts as a cooling device - whether active or passive. So any device that can throttle its performance to passively reduce heat dissipation (e.g. CPUs, GPUs) and any device that can actively dissipate heat at different levels (e.g. fans) will contain this property. Signed-off-by:Amit Kucheria <amit.kucheria@linaro.org> Reviewed-by:
Rob Herring <robh@kernel.org> Reviewed-by:
Lukasz Luba <lukasz.luba@arm.com> Signed-off-by:
Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/7a9ead7fb67585fb70ab3ffd481e7d567e96970e.1585748882.git.amit.kucheria@linaro.org