Commit 72969073 authored by Wilken Gottwalt's avatar Wilken Gottwalt Committed by Guenter Roeck
Browse files

hwmon: (corsair-psu) Fix fan rpm calculation



The correct fan rpm value is also a LINEAR11 value but without a factor.
Verified by using the fan test button on the psu to let the fan spin up
to maximum for some seconds.

Fixes: 933222c98445 ("hwmon: (corsair-psu) fix unintentional sign extension issue")
Signed-off-by: default avatarWilken Gottwalt <wilken.gottwalt@posteo.net>
Link: https://lore.kernel.org/r/20201113121954.GA8488@monster.powergraphx.local


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 66d5b034
Loading
Loading
Loading
Loading
+1 −6
Original line number Diff line number Diff line
@@ -252,12 +252,7 @@ static int corsairpsu_get_value(struct corsairpsu_data *priv, u8 cmd, u8 rail, l
		*val = corsairpsu_linear11_to_int(tmp & 0xFFFF) * 1000;
		break;
	case PSU_CMD_FAN:
		/*
		 * this value is best guess, so the calculated value could be wrong, it is hard
		 * to ge the fan to spin in these semi-passive power supplies, which need a
		 * quite high load to do so
		 */
		*val = ((tmp & 0xFF) << 8) + ((tmp >> 8) & 0xFF);
		*val = corsairpsu_linear11_to_int(tmp & 0xFFFF);
		break;
	case PSU_CMD_RAIL_WATTS:
	case PSU_CMD_TOTAL_WATTS: