Commit 6b4814a9 authored by Steve Twiss's avatar Steve Twiss Committed by Lee Jones
Browse files

mfd: da9063: Fix OTP control register names to match datasheets for DA9063/63L



Mismatch between what is found in the Datasheets for DA9063 and DA9063L
provided by Dialog Semiconductor, and the register names provided in the
MFD registers file. The changes are for the OTP (one-time-programming)
control registers. The two naming errors are OPT instead of OTP, and
COUNT instead of CONT (i.e. control).

Cc: Stable <stable@vger.kernel.org>
Signed-off-by: default avatarSteve Twiss <stwiss.opensource@diasemi.com>
Signed-off-by: default avatarLee Jones <lee.jones@linaro.org>
parent 9e364e87
Loading
Loading
Loading
Loading
+3 −3
Original line number Diff line number Diff line
@@ -210,9 +210,9 @@

/* DA9063 Configuration registers */
/* OTP */
#define	DA9063_REG_OPT_COUNT		0x101
#define	DA9063_REG_OPT_ADDR		0x102
#define	DA9063_REG_OPT_DATA		0x103
#define	DA9063_REG_OTP_CONT		0x101
#define	DA9063_REG_OTP_ADDR		0x102
#define	DA9063_REG_OTP_DATA		0x103

/* Customer Trim and Configuration */
#define	DA9063_REG_T_OFFSET		0x104