Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
pc87360: number-skew to init The temp, therm, fan, pwm callbacks all have an offset skew in the code which accommodates attribute numbering conventions under /sys/bus/i2c/devices/9191-6620/ (ie they start at 1) This patch moves that skew into the declaration, and out of the functions (except for therm, where we simplify from 2 skews to 1). The declarative skew is clearer, less error-prone, and more efficient. The use of 11+offset-4 below reflects the fact that the sysfs numbering of these units is 4, 5, 6, but they use internal VLM units 11, 12, 13 to measure the thermistor voltages. There's one remaining skew factor, in *_crit callbacks below, because there are no critical thresholds for voltages 0-10, only for those supporting the thermistors. Signed-off-by:Jim Cromie <jim.cromie@gmail.com> Signed-off-by:
Jean Delvare <khali@linux-fr.org> Signed-off-by:
Greg Kroah-Hartman <gregkh@suse.de>