Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
The C-Media CM6631 USB receiver doesn't respond to changes in sample rate while the interface is active. The same behavior is observed in other UAC2 hardware like the VIA VT1731. Reset the interface after setting the sampling frequency on sample rate changes, to ensure that the sample rate set by snd_usb_init_sample_rate() is used. Otherwise, the device will try to use the sample rate of the previous stream, causing distorted sound on sample rate changes. The reset is performed for all UAC2 devices, as it should not affect a standards compliant device, but it is only necessary for C-Media CM6631, VIA VT1731 and possibly others. Failure to read sample rate from the device is not handled as an error in set_sample_rate_v2(), as (permanent or intermittent) failure to read sample rate isn't essential for a successful sample rate set. Signed-off-by:Torstein Hegge <hegge@resisty.net> Acked-by:
Clemens Ladisch <clemens@ladisch.de> Signed-off-by:
Takashi Iwai <tiwai@suse.de>