Commit 639c1524 authored by Tony Lindgren's avatar Tony Lindgren Committed by Sebastian Reichel
Browse files

power: supply: cpcap-battery: Check voltage before orderly_poweroff



We can get the low voltage interrupt trigger sometimes way too early,
maybe because of CPU load spikes. This causes orderly_poweroff() be
called too easily.

Let's check the voltage before orderly_poweroff in case it was not
yet a permanent condition. We will be getting more interrupts anyways
if the condition persists.

Let's also show the measured voltages for low battery and battery
empty warnings since we have them.

Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: default avatarTony Lindgren <tony@atomide.com>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 8bc8fc08
Loading
Loading
Loading
Loading
+5 −3
Original line number Diff line number Diff line
@@ -562,12 +562,14 @@ static irqreturn_t cpcap_battery_irq_thread(int irq, void *data)
	switch (d->action) {
	case CPCAP_BATTERY_IRQ_ACTION_BATTERY_LOW:
		if (latest->current_ua >= 0)
			dev_warn(ddata->dev, "Battery low at 3.3V!\n");
			dev_warn(ddata->dev, "Battery low at %imV!\n",
				latest->voltage / 1000);
		break;
	case CPCAP_BATTERY_IRQ_ACTION_POWEROFF:
		if (latest->current_ua >= 0) {
		if (latest->current_ua >= 0 && latest->voltage <= 3200000) {
			dev_emerg(ddata->dev,
				  "Battery empty at 3.1V, powering off\n");
				  "Battery empty at %imV, powering off\n",
				  latest->voltage / 1000);
			orderly_poweroff(true);
		}
		break;