If the thermal subsystem returne -EPROBE_DEFER or any other error when hwmon calls devm_thermal_zone_of_sensor_register(), this is silently ignored. I ran into this with an incorrectly defined thermal zone, making it non-existing and thus this call failed with -EPROBE_DEFER assuming it would appear later. The sensor was still added which is incorrect: sensors must strictly be added after the thermal zones, so deferred probe must be respected. Fixes: d560168b ("hwmon: (core) New hwmon registration API") Signed-off-by:Linus Walleij <linus.walleij@linaro.org> Signed-off-by:
Guenter Roeck <linux@roeck-us.net>