Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Most of the implementations behind cfg80211_get_station will not initialize sinfo to zero before manipulating it. For example, the member "filled", which indicates the filled in parts of this struct, is often only modified by enabling certain bits in the bitfield while keeping the remaining bits in their original state. A caller without a preinitialized sinfo.filled can then no longer decide which parts of sinfo were filled in by cfg80211_get_station (or actually the underlying implementations). cfg80211_get_station must therefore take care that sinfo is initialized to zero. Otherwise, the caller may tries to read information which was not filled in and which must therefore also be considered uninitialized. In batadv_v_elp_get_throughput's case, an invalid "random" expected throughput may be stored for this neighbor and thus the B.A.T.M.A.N V algorithm may switch to non-optimal neighbors for certain destinations. Fixes: 7406353d ("cfg80211: implement cfg80211_get_station cfg80211 API") Reported-by:Thomas Lauer <holminateur@gmail.com> Reported-by:
Marcel Schmidt <ff.z-casparistrasse@mailbox.org> Cc: b.a.t.m.a.n@lists.open-mesh.org Signed-off-by:
Sven Eckelmann <sven@narfation.org> Signed-off-by:
Johannes Berg <johannes@sipsolutions.net>