+115
−5
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Make sure that when doing a lock() or an unlock() operation we don't clear the QE bit from Status Register 2. JESD216 revB or later offers information about the *default* Status Register commands to use (see BFPT DWORDS[15], bits 22:20). In this standard, Status Register 1 refers to the first data byte transferred on a Read Status (05h) or Write Status (01h) command. Status register 2 refers to the byte read using instruction 35h. Status register 2 is the second byte transferred in a Write Status (01h) command. Industry naming and definitions of these Status Registers may differ. The definitions are described in JESD216B, BFPT DWORDS[15], bits 22:20. There are cases in which writing only one byte to the Status Register 1 has the side-effect of clearing Status Register 2 and implicitly the Quad Enable bit. This side-effect is hit just by the BFPT_DWORD15_QER_SR2_BIT1_BUGGY and BFPT_DWORD15_QER_SR2_BIT1 cases. Suggested-by:Boris Brezillon <boris.brezillon@collabora.com> Signed-off-by:
Tudor Ambarus <tudor.ambarus@microchip.com> Reviewed-by:
Vignesh Raghavendra <vigneshr@ti.com>
CRA Git | Maintained and supported by SUSTech CRA and CCSE