The 5785 does not use the RXC reference clock. Turning it off is desirable as it saves power. By default, the 50610 enables the RXC reference clock and the 50610M disables it. Presumably this is one of the reasons why the hardware architect chose one over the other. Adding a "rx reference clock disable" flag is not the ideal way to describe the option, as it would force the MAC using a 50610M to set the flag. Ideally we want the flags to represent opt-in behavior that deviates from hardware defaults. Furthermore, the lack of a "disable" flag implies that the requester wants the rx reference clock enabled, which doesn't necessarily follow. By presenting the option as a passive statement (rx reference clock unused) rather than a command, I hope to convey an opt-in option to disable the rx reference clock that falls back to hardware defaults if not set. A secondary benefit of this is that it keeps the intelligence about phy defaults in the broadcom module where it belongs and allows the broadcom module more latitude should a bug arise. Signed-off-by:Matt Carlson <mcarlson@broadcom.com> Reviewed-by:
Michael Chan <mchan@broadcom.com> Signed-off-by:
David S. Miller <davem@davemloft.net>