Commit 2f74156c authored by Arend van Spriel's avatar Arend van Spriel Committed by Greg Kroah-Hartman
Browse files

staging: brcm80211: use fragment number provided in transmit frame



In the transmit path the field seq_ctrl is filled in, but the fragment
number was not properly determined.

Reviewed-by: default avatarRoland Vossen <rvossen@broadcom.com>
Reviewed-by: default avatarPieter-Paul Giesberts <pieterpg@broadcom.com>
Signed-off-by: default avatarFranky Lin <frankyl@broadcom.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@suse.de>
parent 3215b494
Loading
Loading
Loading
Loading
+1 −1
Original line number Diff line number Diff line
@@ -7100,7 +7100,7 @@ brcms_c_d11hdrs_mac80211(struct brcms_c_info *wlc, struct ieee80211_hw *hw,
				scb->seqnum[p->priority]++;

			/* extract fragment number from frame first */
			seq = le16_to_cpu(seq) & FRAGNUM_MASK;
			seq = le16_to_cpu(h->seq_ctrl) & FRAGNUM_MASK;
			seq |= (scb->seqnum[p->priority] << SEQNUM_SHIFT);
			h->seq_ctrl = cpu_to_le16(seq);