Documentation/hwmon/mp2975.rst
0 → 100644
+116
−0
drivers/hwmon/pmbus/mp2975.c
0 → 100644
+769
−0
File added.
Preview size limit exceeded, changes collapsed.
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
Add support for mp295 device from Monolithic Power Systems, Inc. (MPS) vendor. This is a dual-loop, digital, multi-phase controller. This device: - Supports two power rail. - Provides 8 pulse-width modulations (PWMs), and can be configured up to 8-phase operation for rail 1 and up to 4-phase operation for rail 2. - Supports two pages 0 and 1 for telemetry and also pages 2 and 3 for configuration. - Can configured VOUT readout in direct or VID format and allows setting of different formats on rails 1 and 2. For VID the following protocols are available: VR13 mode with 5-mV DAC; VR13 mode with 10-mV DAC, IMVP9 mode with 5-mV DAC. Signed-off-by:Vadim Pasternak <vadimp@nvidia.com> Link: https://lore.kernel.org/r/20200926204957.10268-2-vadimp@nvidia.com [groeck: Cleaned up a couple of error returns; fixed up API changes] Signed-off-by:
Guenter Roeck <linux@roeck-us.net>
File added.
Preview size limit exceeded, changes collapsed.