ARM: dts: imx7d: Add missing cooling device properties for CPUs



The cooling device properties "#cooling-cells" should either be present
for all the CPUs of a cluster or none. If these are present only for a
subset of CPUs of a cluster then things will start falling apart as soon
as the CPUs are brought online in a different order. For example, this
will happen because the operating system looks for such properties in the
CPU node it is trying to bring up, so that it can register a cooling
device.

Add such missing properties.

Signed-off-by: default avatarAnson Huang <Anson.Huang@nxp.com>
Signed-off-by: default avatarShawn Guo <shawnguo@kernel.org>
parent def76ebc
Loading
Loading
Loading
Loading
+1 −0
Original line number Diff line number Diff line
@@ -22,6 +22,7 @@
			reg = <1>;
			clock-frequency = <996000000>;
			operating-points-v2 = <&cpu0_opp_table>;
			#cooling-cells = <2>;
			cpu-idle-states = <&cpu_sleep_wait>;
		};
	};