+10
−1
Loading
Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
The current interrupt handler calls pm_runtime_suspended() to check if the device is suspended or not. However, runtime PM status of the device is only set to suspended once all PM runtime suspend hooks have executed. In case of Intel Lynxpoint we have the device bound to the ACPI power domain and its runtime suspend hook will put the device to D3hot (or D3cold if possible). This means that the device is powered off before its state is set to runtime suspended. While in this state the device might get an interrupt that is meant for another device (as the interrupt line is shared), and because the device is powered off accessing its registers will return 0xffffffff that the driver misinterprets as an invalid state. When this happens user will see messages like below on the console: pxa2xx-spi INT33C0:00: bad message state in interrupt handler Fix this by checking the status register for ~0 and returning IRQ_NONE in that case. Signed-off-by:Mika Westerberg <mika.westerberg@linux.intel.com> Signed-off-by:
Mark Brown <broonie@linaro.org>
CRA Git | Maintained and supported by SUSTech CRA and CCSE