Commit 24bedcb7 authored by Madhavan Srinivasan's avatar Madhavan Srinivasan Committed by Michael Ellerman
Browse files

powerpc/perf: Fix branch event code for power9



Correct "branch" event code of Power9 is "r4d05e". Replace the current
"branch" event code with "r4d05e" and add a hack to use "r10012" as
event code for Power9 DD1.

Fixes: d89f473f ("powerpc/perf: Fix PM_BRU_CMPL event code for power9")
Reported-by: default avatarAnton Blanchard <anton@samba.org>
Signed-off-by: default avatarMadhavan Srinivasan <maddy@linux.vnet.ibm.com>
Signed-off-by: default avatarMichael Ellerman <mpe@ellerman.id.au>
parent 89d8bb16
Loading
Loading
Loading
Loading
+3 −1
Original line number Diff line number Diff line
@@ -16,7 +16,7 @@ EVENT(PM_CYC, 0x0001e)
EVENT(PM_ICT_NOSLOT_CYC,			0x100f8)
EVENT(PM_CMPLU_STALL,				0x1e054)
EVENT(PM_INST_CMPL,				0x00002)
EVENT(PM_BRU_CMPL,				0x10012)
EVENT(PM_BRU_CMPL,				0x4d05e)
EVENT(PM_BR_MPRED_CMPL,				0x400f6)

/* All L1 D cache load references counted at finish, gated by reject */
@@ -56,3 +56,5 @@ EVENT(PM_RUN_CYC, 0x600f4)
/* Instruction Dispatched */
EVENT(PM_INST_DISP,				0x200f2)
EVENT(PM_INST_DISP_ALT,				0x300f2)
/* Alternate Branch event code */
EVENT(PM_BR_CMPL_ALT,				0x10012)
+7 −1
Original line number Diff line number Diff line
@@ -231,7 +231,7 @@ static int power9_generic_events_dd1[] = {
	[PERF_COUNT_HW_STALLED_CYCLES_FRONTEND] =	PM_ICT_NOSLOT_CYC,
	[PERF_COUNT_HW_STALLED_CYCLES_BACKEND] =	PM_CMPLU_STALL,
	[PERF_COUNT_HW_INSTRUCTIONS] =			PM_INST_DISP,
	[PERF_COUNT_HW_BRANCH_INSTRUCTIONS] =		PM_BRU_CMPL,
	[PERF_COUNT_HW_BRANCH_INSTRUCTIONS] =		PM_BR_CMPL_ALT,
	[PERF_COUNT_HW_BRANCH_MISSES] =			PM_BR_MPRED_CMPL,
	[PERF_COUNT_HW_CACHE_REFERENCES] =		PM_LD_REF_L1,
	[PERF_COUNT_HW_CACHE_MISSES] =			PM_LD_MISS_L1_FIN,
@@ -453,6 +453,12 @@ static int __init init_power9_pmu(void)
		 * sampling scenarios in power9 DD1, instead use PM_INST_DISP.
		 */
		EVENT_VAR(PM_INST_CMPL, _g).id = PM_INST_DISP;
		/*
		 * Power9 DD1 should use PM_BR_CMPL_ALT event code for
		 * "branches" to provide correct counter value.
		 */
		EVENT_VAR(PM_BRU_CMPL, _g).id = PM_BR_CMPL_ALT;
		EVENT_VAR(PM_BRU_CMPL, _c).id = PM_BR_CMPL_ALT;
		rc = register_power_pmu(&power9_isa207_pmu);
	} else {
		rc = register_power_pmu(&power9_pmu);