Voltage regulators can have (unregulated) current limits too, so we should
probably output both voltage and current for all regulators.
Holding the rdev->mutex actually conflicts with _regulator_get_current_limit
but also is not really necessary, as the global regulator_list_mutex already
protects us from the regulator vanishing while we go through the list.
On the rk3288-firefly the summary now looks like:
regulator use open bypass voltage current min max
-------------------------------------------------------------------------------
vcc_sys 0 12 0 5000mV 0mA 5000mV 5000mV
vcc_lan 1 1 0 3300mV 0mA 3300mV 3300mV
ff290000.ethernet 0mV 0mV
vcca_33 0 0 0 3300mV 0mA 3300mV 3300mV
vcca_18 0 0 0 1800mV 0mA 1800mV 1800mV
vdd10_lcd 0 0 0 1000mV 0mA 1000mV 1000mV
[...]
Suggested-by:
Mark Brown <broonie@kernel.org>
Signed-off-by:
Heiko Stuebner <heiko@sntech.de>
Signed-off-by:
Mark Brown <broonie@kernel.org>