Gitlab 现已全面支持 git over ssh 与 git over https。通过 HTTPS 访问请配置带有 read_repository / write_repository 权限的 Personal access token。通过 SSH 端口访问请使用 22 端口或 13389 端口。如果使用CAS注册了账户但不知道密码,可以自行至设置中更改;如有其他问题,请发邮件至 service@cra.moe 寻求协助。
In tegra_powergate_set() the state of the powergates is read and OR'ed with the bit for the powergate of interest. This unsigned 32-bit value is then compared with a boolean value to test if the powergate is already in the desired state. When turning on a powergate, apart from the powergate that is represented by bit 0, this test will always return false and so we may attempt to turn on the powergate when it is already on. After OR'ing the bit for the powergate, check if the result is not equal to zero before comparing with the boolean value. Add a helper function to return the current state of a powergate and use this in both tegra_powergate_set() and tegra_powergate_is_powered() where we check the powergate status. Signed-off-by:Jon Hunter <jonathanh@nvidia.com> Reviewed-by:
Mathieu Poirier <mathieu.poirier@linaro.org> Signed-off-by:
Thierry Reding <treding@nvidia.com>