Commit 0981582d authored by Roland Dreier's avatar Roland Dreier
Browse files

mlx4_core: Change command token on timeout


    
The FW command token is currently only updated on a command completion
event. This means that on command timeout, the same token will be
reused for new command, which results in a mess if the timed out
command *does* eventually complete.

This is the same change as the patch for mthca from Michael
S. Tsirkin <mst@dev.mellanox.co.il> that was just merged.  It seems
sensible to avoid gratuitous differences in FW command processing
between mthca and mlx4.

Signed-off-by: default avatarRoland Dreier <rolandd@cisco.com>
parent c1f74958
Loading
Loading
Loading
Loading
+1 −2
Original line number Diff line number Diff line
@@ -246,8 +246,6 @@ void mlx4_cmd_event(struct mlx4_dev *dev, u16 token, u8 status, u64 out_param)
	context->result    = mlx4_status_to_errno(status);
	context->out_param = out_param;

	context->token += priv->cmd.token_mask + 1;

	complete(&context->done);
}

@@ -264,6 +262,7 @@ static int mlx4_cmd_wait(struct mlx4_dev *dev, u64 in_param, u64 *out_param,
	spin_lock(&cmd->context_lock);
	BUG_ON(cmd->free_head < 0);
	context = &cmd->context[cmd->free_head];
	context->token += cmd->token_mask + 1;
	cmd->free_head = context->next;
	spin_unlock(&cmd->context_lock);