Commit 00999d99 authored by Dmytro Laktyushkin's avatar Dmytro Laktyushkin Committed by Alex Deucher
Browse files

drm/amd/display: clean up validation failure log spam



Currently dcn2+ validation will unconditionally print a failure
reason before validation completes. This change categorizes the
failure reason as a warning log and only prints at the end of
validation resolving false positives.

Signed-off-by: default avatarDmytro Laktyushkin <Dmytro.Laktyushkin@amd.com>
Reviewed-by: default avatarNikola Cornij <Nikola.Cornij@amd.com>
Acked-by: default avatarLeo Li <sunpeng.li@amd.com>
Signed-off-by: default avatarAlex Deucher <alexander.deucher@amd.com>
parent 0cd32625
Loading
Loading
Loading
Loading
+3 −0
Original line number Diff line number Diff line
@@ -1880,6 +1880,7 @@ bool dcn20_validate_bandwidth(struct dc *dc,
	int split_threshold = dc->res_pool->pipe_count / 2;
	bool avoid_split = dc->debug.pipe_split_policy != MPC_SPLIT_DYNAMIC;
	display_e2e_pipe_params_st *pipes = kzalloc(dc->res_pool->pipe_count * sizeof(display_e2e_pipe_params_st), GFP_KERNEL);
	DC_LOGGER_INIT(dc->ctx->logger);

	ASSERT(pipes);
	if (!pipes)
@@ -2183,6 +2184,8 @@ validate_pass:
	return true;

validate_fail:
	DC_LOG_WARNING("Mode Validation Warning: %s failed validation.\n",
		dml_get_status_message(context->bw_ctx.dml.vba.ValidationStatus[context->bw_ctx.dml.vba.soc.num_states]));
	kfree(pipes);
	return false;
}
+1 −11
Original line number Diff line number Diff line
@@ -75,16 +75,6 @@ unsigned int dml_get_voltage_level(
	}
	mode_lib->funcs.validate(mode_lib);

	/* check if Mode Support Validation failed */
	if (mode_lib->vba.VoltageLevel > mode_lib->vba.soc.num_states) {
		/* get the validation status for highest voltage level and output console message */
		enum dm_validation_status status = mode_lib->vba.ValidationStatus[mode_lib->vba.soc.num_states];
		if (status != DML_FAIL_PITCH_SUPPORT) {
			/*AlignedYPitch is based on swizzle mode, so it is normal if some swizzle mode not supported*/
			dm_output_to_console("Mode Validation Error: %s failed validation.\n", dml_get_status_message(status));
		}
	}

	return mode_lib->vba.VoltageLevel;
}